For a fire to start, three components of the triangle namely: Fuel, Oxygen and Ignition sources need to come together (Figure).

 

Figure: Components that cause a fire on coming together

 

 

  • Fire will not start if any one of these components is missing.
  • The laboratory personnel should ensure these three components will not come together, to reduce the chance of fire in the laboratory.
  • Engineering controls and a variety of fire prevention and suppression strategies should be part of laboratory safety protocols.

 

Common Causes of Fires in TB Laboratories 

  • Electrical circuit overloading
  • Poor electrical maintenance, e.g., poor and perished cable insulation
  • Excessively long gas tubing or long electrical leads
  • Equipment unnecessarily left switched on
  • Equipment that was not designed for the laboratory environment
  • Open flames
  • Deteriorated gas tubing
  • Improper handling and storage of flammable or explosive materials
  • Improper segregation of incompatible chemicals
  • Sparking equipment near flammable substances and vapours
  • Improper or inadequate ventilation

 

Considerations for Fire Safety

  • Close cooperation between safety officers and local fire prevention officers is essential.
  • The effect of fire on the possible dissemination of infectious material must be considered as this may determine whether it is best to extinguish or contain the fire.
  • Fire warnings, instructions and escape routes should be displayed prominently in rooms, corridors and hallways.
  • Fire-fighting equipment should be placed near room doors and at strategic points in corridors and hallways.
  • Fire extinguishers should be regularly inspected and maintained, and their shelf-life kept up to date.

 

General Measures to Handle Fire in the Laboratory

  • All lab personnel must learn how to operate a fire extinguisher.
  • Fire extinguisher must be inspected annually and replaced as needed.
  • Laboratory should have appropriate class of fire extinguisher.
  • In general Class BC or class ABC extinguisher is appropriate.
  • The contact information for reaching out to the fire department, should be posted at various locations in the lab.

Table: Types and Uses of Fire Extinguishers

 

 

Prevention of Fire due to Electrical Hazards  

  1. Electrical installations and equipment should be inspected and tested regularly, including earthing/ grounding systems.
  2. Circuit-breakers and earth-fault-interrupters should be installed in appropriate laboratory electrical circuits.
  3. Circuit-breakers do not protect people; they are intended to protect wiring from being overloaded with electrical current, and hence to prevent fires. 
  4. Earth-fault-interrupters are intended to protect people from electric shock.
  5. All laboratory electrical equipment should be earthed/ grounded, preferably through three-prong plugs.
  6. All laboratory electrical equipment and wiring should conform to national electrical safety standards and codes.

 